Tony Thigpen wrote:

>The remote operator is a human.
>Tape management system is CA1
>Still researching logs.

Thanks. I see that output and logs you gave to Lizette.

I see you have MOUNT WAIT TIME=010 MINUTE(S), but what are the [elapsed] times 
for these messages and reply?

*IEC501A M 0C01,015010,SL,COMP,DFSMSHSM,DFSMSHSM,DFHSM.BACKTAPE.DATASET
*0037 ARC0310A CAN TAPE 015010 BE MOUNTED? REPLY Y OR N
  R 37,N

You said it asked for another mount, is that for this message for which you 
drove in your car to do that mount? 

ARC0421I BACKUP VOLUME 015010 IS NOW MARKED FULL

Just probing questions, because when I was a HSM admin ages ago, I got many 
gray hairs about those mounts...

It is one of those things for which an autoreply is not going to work always in 
a 'lights-out 24/7' environment.

Good luck! You will need all the help you are deserving. I hope you can get a 
good solution for this PITA.

Groete / Greetings
Elardus Engelbrecht

----------------------------------------------------------------------