If these are Linklst'd datasets, then you could 
  1) Build a new LINKLST and remove these datasets in the new LINKLST
  2) Do what you need to with these files (move, delete)
  3) then if you need them back, build a new copy of the linklst

 Everything will depend on what these datasets are and what they are used for 
in your environment.

 It  is a little bit more difficult to provide a better answer.  There are very 
few details to understand the issue.

 Are they in the LINKLST?
 Are they in other processes?  JCL for STCs, for example.
 What are they used for?
 
 
 Lizette


> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On
> Behalf Of Ravi Gaur
> Sent: Thursday, January 05, 2017 2:40 AM
> To: IBM-MAIN@LISTSERV.UA.EDU
> Subject: Delete NVR entries where ENQ shows from LLA/XCFAS
> 
> Delete datasets from Disk/3390 which are having enqueue from LLA/XCFAS
> ....Tried IDCAMS NVR and also ISPF 3.2 (with VOLUME serial no.) get in use
> message any trick to get the datasets deleted via bypassing enqueue? on this
> specific volume
> 

----------------------------------------------------------------------