OK - I overlooked that :-( <grin> On 17/03/2017 22:42, Jesse 1 Robinson wrote: > Sysmods can be (usually are) deleted from SMPPTS during ACCEPT. That's an > update. > > . > . > J.O.Skip Robinson > Southern California Edison Company > Electric Dragon Team Paddler > SHARE MVS Program Co-Manager > 323-715-0595 Mobile > 626-543-6132 Office ⇐=== NEW > [email protected] > > > -----Original Message----- > From: IBM Mainframe Discussion List [mailto:[email protected]] On > Behalf Of CM Poncelet > Sent: Friday, March 17, 2017 3:29 PM > To: [email protected] > Subject: (External):Re: Can SMPPTS datasets be consolidated? > > Yes indeed. Anything can be done in SMP/E via UCLIN - e.g. "DEL GZONE > ZONEINDEX(<whatever>)" + "ADD GZONE ZONEINDEX (<whatever>)" and then "SET > BOUNDARY(GLOBAL)" + "UCLIN" + "REP DDDEF(SMPPTS) DA(<whatever > else>) SHR" ... and so forth. > > What matters is to use native SMP/E in batch instead of IBM's "SMP/E for > Dummies" dialogs. > > BTW SMPPTS is written to only during RECEIVE. Else it is only read. > > > On 17/03/2017 01:13, Steve Beaver wrote: >> You can concatenate them or just build a new SMPPTS and change the >> name in the DDEF >> >> https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.2.0/com.ibm.zo >> s.v2r2.gim2000/dspts1.htm >> >> >> -----Original Message----- >> From: IBM Mainframe Discussion List [mailto:[email protected]] >> On Behalf Of Dan Little >> Sent: Thursday, March 16, 2017 7:58 PM >> To: [email protected] >> Subject: Re: Can SMPPTS datasets be consolidated? >> >> I thought the SMMPTSx DDDEF was recorded in the global zone and that >> consolidating could not easily be done. >> >> >> Dan >> >> >> On Thu, Mar 16, 2017 at 19:26 Gibney, Dave <[email protected]> wrote: >> >>> Has this always been so. Sometime ago (1.7, 1.9) I had ACCEPT fail >>> because I had compressed and moved members into lower sequenced >>> SMPPTSn At least I think I remember this. I've just always added >>> another SMPPTSz ever since. >>> >>>> -----Original Message----- >>>> From: IBM Mainframe Discussion List >>>> [mailto:[email protected]] On Behalf Of Jesse 1 Robinson >>>> Sent: Thursday, March 16, 2017 3:45 PM >>>> To: [email protected] >>>> Subject: Re: Can SMPPTS datasets be consolidated? >>>> >>>> SMP/E does not keep a permanent record of which PTS holds a >>>> particular sysmod. On every query, the concatenated PTS libraries >>>> are searched. If >>> the >>>> sysmod is found, the particular library is named, otherwise 'not found'. >>> This >>>> allows you to freely manipulate the libraries and their content. >>>> Worst >>> case, >>>> after consolidating PTS libraries, exit and re-enter the SMP/E dialog. >>>> >>>> . >>>> . >>>> J.O.Skip Robinson >>>> Southern California Edison Company >>>> Electric Dragon Team Paddler >>>> SHARE MVS Program Co-Manager >>>> 323-715-0595 Mobile >>>> 626-543-6132 Office ⇐=== NEW >>>> [email protected] >>>> >>>> >>>> -----Original Message----- >>>> From: IBM Mainframe Discussion List >>>> [mailto:[email protected]] On Behalf Of Gibney, Dave >>>> Sent: Thursday, March 16, 2017 1:37 PM >>>> To: [email protected] >>>> Subject: (External):Re: Can SMPPTS datasets be consolidated? >>>> >>>> I am not sure the process. I'd advise adding more secondary PPTS >>> datasets. >>>> SMP/E remembers which PPTS a given PTF is in. >>>> >>>>> -----Original Message----- >>>>> From: IBM Mainframe Discussion List >>>>> [mailto:[email protected]] On Behalf Of Allan Staller >>>>> Sent: Thursday, March 16, 2017 1:34 PM >>>>> To: [email protected] >>>>> Subject: Re: Can SMPPTS datasets be consolidated? >>>>> >>>>> YES-----Original Message-----From: IBM Mainframe Discussion List >>>>> [mailto:[email protected]] On Behalf Of Herring, BobbySent: >>>>> Thursday, March 16, 2017 3:30 PMTo: IBM- >>>> [email protected]: >>>>> Can SMPPTS datasets be consolidated?I am in the process of >>>>> receiving a large RSU maintenance order. I have filled up three >>>>> SMPPTS datasets that were not defined large enough.Can these be >>>>> merged and consolidated into one or two much larger datasets?Bobby >>>>> HerringTexas Farm Bureau > > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN >
---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN
