The OP could also try D GRS,C on the surviving system. -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Carmen Vitullo Sent: Thursday, April 19, 2018 1:03 PM To: [email protected] Subject: Re: SYSPLEX Hung
not sure if this would help, since I suspect maybe JES2 was a victim, of a deadly embrace. since you didn't get a chance to take a SADMP the RMF ENQ report may help diagnose an ENQ, or RESERVE issue. I'd like to also assume all shared DASD is within the same SYSPLEX? Carmen Vitullo ----- Original Message ----- From: "Salah Balboul" <[email protected]> To: [email protected] Sent: Thursday, April 19, 2018 11:55:37 AM Subject: Re: SYSPLEX Hung In JES MAS, yes. CKPT on DASD. Nothing but ckpt on each DASD. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN ::DISCLAIMER:: -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- The contents of this e-mail and any attachment(s) are confidential and intended for the named recipient(s) only. E-mail transmission is not guaranteed to be secure or error-free as information could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or may contain viruses in transmission. The e mail and its contents (with or without referred errors) shall therefore not attach any liability on the originator or HCL or its affiliates. Views or opinions, if any, presented in this email are solely those of the author and may not necessarily reflect the views or opinions of HCL or its affiliates. Any form of reproduction, dissemination, copying, disclosure, modification, distribution and / or publication of this message without the prior written consent of authorized representative of HCL is strictly prohibited. If you have received this email in error please delete it and notify the sender immediately. Before opening any email and/or attachments, please check them for viruses and other defects. -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN