On Fri, 25 May 2018 17:39:03 +0000, Jesse 1 Robinson wrote:
>
>As for getting inconsistent results, I suspect that SMP/E results can be 
>influenced by the particular mix of elements being processed in a given run. 
>That is, applying SYSMOD-A and SYSMOD-B in the same step might uncover a 
>sinkhole that applying one sysmod or the other alone would not. This problem 
>is very difficult to detect in development and may require a lot of customer 
>activity to unearth. 
> 
Indeed.  Does this happen when SYSMOD-A delivers a new ++MOD element
and SYSMOD-B delivers ++JCLIN adding that ++MOD element to an existing
load module?

-- gil

----------------------------------------------------------------------