When I have these types of issues, I go back to the vendor to find out what is
needed to resolve the issue. This could be something in the way they coded the
SMP/e fixes or in the way I am trying to apply maintenance.
I do not do anything fancy with maintenance.
If you could post your SMP/e control cards - there might be something we see in
the way they are coded.
I usually do a
APPLY CHECK Bypass(HOLDSYS) S(x y z) .
>From what I have seen over the years, this usually will work.
And I will tend to use the SMP/e panels in ISPF to build my JCL. Saves a lot
of time in building the jobs.
Lizette
> -----Original Message-----
> From: IBM Mainframe Discussion List <[email protected]> On Behalf Of
> Peter
> Sent: Sunday, August 25, 2019 12:21 AM
> To: [email protected]
> Subject: GIM38201E and GIM31901I
>
> Hi
>
> I am apply RSU for our zOS system. I am receiving a error message
>
> GIM38201E ** THERE IS A MODID ERROR FOR MOD ENTRY EZBTCRDF IN SYSMOD UI34556
>
> GIM31901I SYSMOD UI34556 DOES NOT SPECIFY UI46897 ON PRE OR SUP OPERAND.
> UI46897 IS THE RMID FOR MOD EZBTCRDF THAT IS CURRENTLY INSTALLED.
>
> GIM22601I APPLY PROCESSING FAILED FOR SYSMOD UI34556.
>
> Does it mean the PTF UI46897 applied should be restored and modify its MCS to
> add UI34556 as its PRE ?
>
> Is my understanding correct?
>
> Could someone please shed light on ?
>
> zOS 2.2
>
> Peter
>
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN