Hi Lizette,
GROUPEXTEND (abbreviation GEXT) should always be coded.

Regards,
David

On 2019-08-25 09:56, Lizette Koehler wrote:
> When I have these types of issues, I go back to the vendor to find out what 
> is needed to resolve the issue.  This could be something in the way they 
> coded the SMP/e fixes or in the way I am trying to apply maintenance.
>
> I do not do anything fancy with maintenance.
>
> If you could post your SMP/e control cards - there might be something we see 
> in the way they are coded.
>
> I usually do a
>
>        APPLY CHECK Bypass(HOLDSYS) S(x y z)  .
>
> >From what I have seen over the years, this usually will work.
>
> And I will tend to use the SMP/e panels in ISPF to build my JCL.  Saves a lot 
> of time in building the jobs.
>
> Lizette
>
>
>> -----Original Message-----
>> From: IBM Mainframe Discussion List <[email protected]> On Behalf Of
>> Peter
>> Sent: Sunday, August 25, 2019 12:21 AM
>> To: [email protected]
>> Subject: GIM38201E and GIM31901I
>>
>> Hi
>>
>> I am apply RSU for our zOS system. I am receiving a error message
>>
>> GIM38201E ** THERE IS A MODID ERROR FOR MOD ENTRY EZBTCRDF IN SYSMOD UI34556
>>
>> GIM31901I SYSMOD UI34556 DOES NOT SPECIFY UI46897 ON PRE OR SUP OPERAND.
>> UI46897 IS THE RMID FOR MOD EZBTCRDF THAT IS CURRENTLY INSTALLED.
>>
>> GIM22601I  APPLY PROCESSING FAILED FOR SYSMOD UI34556.
>>
>> Does it mean the PTF UI46897 applied should be restored and modify its MCS to
>> add UI34556 as its PRE ?
>>
>> Is my understanding correct?
>>
>> Could someone please shed light on ?
>>
>> zOS 2.2
>>
>> Peter
>>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
> .
>


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to