On Tue, 28 Apr 2020 11:47:23 +1000, Wayne Bickerdike wrote:

>Doesn't seem right to me. If we're takling ANSI carriage control.
>
I think they're talking MVT COBOL syntax.

>0 - move double
>blank - move single
>+ - no LF
>1 - Skip to next page (Channel 1)
>
>We always used machine code characters because they didn't have to be
>immediate whereas ANSI were immediate. The reasoning was that it was faster
>to perform the print action and then do the carriage move to the next line
>or channel. In the days of the 1403 line printer.
> 
Is that a guess, or did someone actually perform measurements?

I would hope that a well-designed printer driver would optimize channel
programs as it converted from ANSI to CCWs.  The controller always
performs spacing after printing.

-- gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to