Setahu saya, Veritas NetBackup menggunakan 3 tiers:
- Master server : tempat utk mengatur NetBackup environment
- Media server (optional): tempat utk backup-media :local backup or across 
network
- Client (database) server : misalnya : Target Database yg akan dibackup 
menggunakan NetBackup

Jadi, tempat utk menyimpan hasil backupnya adalah di Media Server, yg secara 
fisik bisa terpisah dgn database server.

bw

--- In [email protected], "Herry Yusirwan" <herry.yusir...@...> wrote:
>
> Terima kasih atas pencerahannya, mas yulius.
> 
> Saya berpikir kenapa RMAN tidak bisa melakukannya? Apa perlu tambahan
> software lainnya agar dapat membackup diluar server dari target
> databasenya.
> 
> Setahu saya, veritas itu memakai fungsi RMAN untuk melakukan backup pada
> oracle database dan veritas bisa langsung mengcopy file tersebut.
> 
> Apakah mas yulius punya penjelasan mengenai ini?
> 
>  
> 
> Terima kasih
> 
>  
> 
> Rgds,
> 
> Herry
> 
>  
> 
>  
> 
> From: [email protected] [mailto:[email protected]]
> On Behalf Of Yulius Wibowo
> Sent: 18 Mei 2009 11:26
> To: [email protected]
> Subject: [indo-oracle] Re: RMAN
> 
>  
> 
> 
> 
> 
> 
> 
> Kang Hery,
> RMAN adalah backup/recovery tool yg bersifat server-based. 
> Artinya, process backup/recovery & hasil backup dilakukan dan disimpan
> di target database.
> 
> Catalog database dipakai utk menyimpan informasi mengenai target
> database (metadata) 
> & informasi mengenai backup/recovery yg pernah dilakukan.
> Catalog database dipakai sbg suplemen(?) dari target database
> controlfile.
> Selain itu juga bisa dipakai utk menyimpan informasi backup 
> dengan retention yg cukup lama (baca:forever. Kalau menggunakan
> controlfile, default-nya hanya 7 hari).
> 
> CMIIW,
> bw
> 
> --- In [email protected]
> <mailto:indo-oracle%40yahoogroups.com> , "Herry Yusirwan"
> <herry.yusirwan@> wrote:
> >
> > Dear All,
> > 
> > 
> > 
> > Saya memakai windows 2003 operating system dan oracle 9i dan saya
> perlu
> > pencerahan mengenai RMAN.
> > 
> > Setelah saya pelajari dan coba ternyata RMAN hanya bisa menghasilkan
> > backup pada lokasi target database, tidak bisa pada lokasi catalog
> > database (asumsi: target catalog db memakai server yang berbeda).
> > 
> > Apakah kemampuan RMAN hanya seperti itu? Atau bisa lebih ? 
> > 
> > 
> > 
> > Mohon pencerahannya
> > 
> > 
> > 
> > Terima kasih
> > 
> > 
> > 
> > Rgds,
> > 
> > Herry
> > 
> > 
> > 
> > 
> > 
> > 
> > 
> > DISCLAIMER:
> > This Message is confidential; it contents does not constitute a
> commitment by PT. INDONESIA POWER, except where provided for in a
> written agreement between you and PT. INDONESIA POWER. Any unauthorized
> disclosure, use or dissemination of the content, either whole or
> partial, is strictly prohibited. If you are not the intended recipient
> of the message or you have received this electronic transmission in
> error, please notify or contact the sender immediately.
> > 
> > PT.INDONESIA POWER is subsidiary of PT. PLN PERSERO which operates in
> power generating business. Through its 130 power plants, with a total
> capacity of 8,872 MW, PT.INDONESIA POWER has contributed significantly
> to the Java Bali interconnection system electricity supply. PT.INDONESIA
> POWER operates through its eight generating Business Unit (GBU) :
> Suralaya, Priok, Saguling, Kamojang, Mrica, Semarang, Perak Grati, Bali
> and one maintenance Services business unit (MSBU).
> > Scanned by IronPort Email Security Gateway
> > 
> > 
> > [Non-text portions of this message have been removed]
> >
> 
> 
> 
> Scanned by IronPort Email Security Gateway
> 
> 
> DISCLAIMER:
> This Message is confidential; it contents does not constitute a commitment by 
> PT. INDONESIA POWER, except where provided for in a written agreement between 
> you and PT. INDONESIA POWER. Any unauthorized disclosure, use or 
> dissemination of the content, either whole or partial, is strictly 
> prohibited. If you are not the intended recipient of the message or you have 
> received this electronic transmission in error, please notify or contact the 
> sender immediately.
> 
> PT.INDONESIA POWER is subsidiary of PT. PLN PERSERO which operates in power 
> generating business. Through its 130 power plants, with a total capacity of 
> 8,872 MW, PT.INDONESIA POWER has contributed significantly to the Java Bali 
> interconnection system electricity supply. PT.INDONESIA POWER operates 
> through its eight generating Business Unit (GBU) : Suralaya, Priok, Saguling, 
> Kamojang, Mrica, Semarang, Perak Grati, Bali and one maintenance Services 
> business unit (MSBU).
> Scanned by IronPort Email Security Gateway
> 
> 
> [Non-text portions of this message have been removed]
>


Kirim email ke