What OS are you using?

On Sunday, 21 September 2014 18:26:26 UTC+1, AF wrote:
>
> black7 thank you for your comment.
>
> This is really frustrating... what's strange is this:
>
> 1. now I am connecting the board to the PC always in A position and 
> ioiodude can always read the Bootloader version (when in boot mode).
> 2. however ioiodude cannot read the Application version (when not in boot 
> mode).
>
> Also there's another thing:
>
> 3. when I connect the smartphone to the IOIO (IOIO with external supply + 
> OTG cable "master side" connected to IOIO's micro-USB port) it comunicates 
> with the smartphone in both H or A positions!
> 4. however when I connect the cable "master side" to the micro-USB port of 
> the smartphone it can feed the IOIO but cannot communicate with it (in this 
> case IOIO has no external supply)...
>
> I think there is a problem with the IOIO when in Acessory mode and I don't 
> what it is... it seems to not communicate with both PC and smartphone in 
> this mode.
> I think I tried almost everything. Rebooting PC, installing new ioio.inf 
> file, writing new app firmware, etc... And everything in Eclipse is matched 
> by the way because I have another board with v5 app firmware (ioiodude 
> reads both bootloader and app firmware) and the app I developed works just 
> fine when the IOIO has no external supply and the smartphone is host.
>
> Domingo, 21 de Setembro de 2014 15:49:53 UTC+1, [email protected] 
> escreveu:
>>
>> Oh Man...Your problems sound just like mine several month ago.
>>
>> When connect via USB to the PC, the OTG switch needs to be A (auto).
>>
>> Regarding port number double check everything, and then reboot the PC, 
>> particularly if you have the IDE running like Eclipse. I would also reload 
>> the new firmware.
>>
>> One other gotcha with the new firmware - be sure everything in the IDE is 
>> matched to the firmware.
>>
>> When you connect the phone via USB, the OTG needs to be H (host), if you 
>> are connecting BlueTooth dongle switch it to A.
>>
>>
>> Hope this helps.
>>
>>
>> On Saturday, September 20, 2014 7:48:58 PM UTC-7, AF wrote:
>>>
>>> Hello all IOIO users.
>>>
>>> My IOIO-OTG had application firmware version 0300 and was working fine 
>>> at first.
>>> Recently I have upgraded its application firmware to version 0500 so I 
>>> used ioiodude to do it and the operation was aparently successfull (....... 
>>> Done.).
>>> However now when I try to connect it to my PC in bootloader mode the PC 
>>> recognizes it and shows me the COM port but when in application mode it 
>>> simply doesn't recognizes it and gives me an USB error... Also, the 
>>> IOIO-OTG doesn't communicate with my smartphone anymore... But the red 
>>> light still turns on!
>>> I can read the bootloader firmware version with ioiodude but not the 
>>> application firmware because the command line freezes when I try to do 
>>> this...
>>> What could be wrong? Is it possible that I fried the IOIO-OTG? I am 
>>> thinking of that "H-A" switch because I read somewhere that we should 
>>> connect the IOIO-OTG to the PC in "A" position... and I can't remember if I 
>>> put it in "H" or "A" position when I upgraded the application firmware... 
>>> Can you tell me what is the problem? Any help would be appreciated.
>>>
>>

-- 
You received this message because you are subscribed to the Google Groups 
"ioio-users" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to [email protected].
To post to this group, send email to [email protected].
Visit this group at http://groups.google.com/group/ioio-users.
For more options, visit https://groups.google.com/d/optout.

Reply via email to