https://issues.apache.org/jira/browse/DRILL-4373?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15585691#comment-15585691
]
ASF GitHub Bot commented on DRILL-4373:
---------------------------------------
Github user vdiravka commented on a diff in the pull request:
https://github.com/apache/drill/pull/600#discussion_r83852721
--- Diff:
exec/java-exec/src/test/java/org/apache/drill/exec/physical/impl/writer/TestParquetWriter.java
---
@@ -899,18 +883,21 @@ public void testLastPageOneNull() throws Exception {
"cp.`parquet/last_page_one_null.parquet`");
}
- private void compareParquetInt96Converters(String newInt96ConverterQuery,
- String oldInt96ConverterAndConvertFromFunctionQuery) throws
Exception {
- testBuilder()
- .ordered()
- .sqlQuery(newInt96ConverterQuery)
- .optionSettingQueriesForTestQuery(
- "alter session set `%s` = true",
ExecConstants.PARQUET_READER_INT96_AS_TIMESTAMP)
- .sqlBaselineQuery(oldInt96ConverterAndConvertFromFunctionQuery)
- .optionSettingQueriesForBaseline(
- "alter session set `%s` = false",
ExecConstants.PARQUET_READER_INT96_AS_TIMESTAMP)
- .build()
- .run();
+ private void compareParquetInt96Converters(String selection, String
table) throws Exception {
+ try {
--- End diff --
I refactored my helped method with more clear code.
> Drill and Hive have incompatible timestamp representations in parquet
> ---------------------------------------------------------------------
>
> Key: DRILL-4373
> URL: https://issues.apache.org/jira/browse/DRILL-4373
> Project: Apache Drill
> Issue Type: Improvement
> Components: Storage - Hive, Storage - Parquet
> Affects Versions: 1.8.0
> Reporter: Rahul Challapalli
> Assignee: Karthikeyan Manivannan
> Labels: doc-impacting
> Fix For: 1.9.0
>
>
> git.commit.id.abbrev=83d460c
> I created a parquet file with a timestamp type using Drill. Now if I define a
> hive table on top of the parquet file and use "timestamp" as the column type,
> drill fails to read the hive table through the hive storage plugin
> Implementation:
> Added int96 to timestamp converter for both parquet readers and controling it
> by system / session option "store.parquet.int96_as_timestamp".
> The value of the option is false by default for the proper work of the old
> query scripts with the "convert_from TIMESTAMP_IMPALA" function.
> When the option is true using of that function is unnesessary and can lead to
> the query fail.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)