On 2010/11/09 21:41, Sebastien Lelong wrote:

If you look at unittest results, it seems we don't calculate tad values
the same way. It's probably expected but it's worth having a look and check.

The new adc_clock calculates Tad the other way around than the old library. As a result the new Tad values are lower (that was one of my goals), meaning faster A-D conversion. Sorry, I didn't think of this effect on unit test results! Can you easily change the unittests?

Regards, Rob.


--