Jerry, Most annoying thing - it does not provide redundant power to the switches. I could live with other problems, but this one is kind of a deal breaker. I have all 3 AC PS inserted. I have 4 DC outlets connected to 4 EX3300 switches. I have console port on RPS connected to console server and I can get access to some crippled shell inside it. when I issue command "show chassis redundant-power-system" on the switch with DC connected to RPS, I got following answer: "error: No RPS connected (chassis-control)"
nick On Thu, Jul 4, 2013 at 7:58 PM, Jerry Jones <[email protected]> wrote: > Only gotcha I have heard of is to use the center slot for the first power > supply. > > What specifically is it not doing? > > > On Jul 4, 2013, at 9:04 AM, Nick Kritsky <[email protected]> wrote: > > Hello all, > > Is anyone here who has experience with EX-RPS - redundant power supply for > EX switches? > I'd like to ask some questions/directions . > > From what I see - basically they are just DC converters with some minimal > set of knobs. > Documentation is virtually non-existent. Main idea I got from the site - it > should just work when you plug it in. But guess what - it doesn't. It > looks like I have missed some very simple step. The one that was considered > obvious to the guy who was creating the manual :) > > thanks > nick > _______________________________________________ > juniper-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/juniper-nsp > > _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp