Thanks, I will try that. And I will file the case with JTAC as well. Could it be that RPS would only work with switches running 12.x ?
For example documentation says about "show redundant-power-system version" - "Command introducedin Junos OS Release 12.1 for EX Series switches". The command is recognized in 11.3R4.2 . If I recall correctly - EX-RPS was there before 12.x . nick On Thu, Jul 4, 2013 at 8:58 PM, Jerry Jones <[email protected]> wrote: > Couple ideas to try. > > You say switches have internal DC power so I guess there is no POE. If so > then when you get a switch up I would suggest setting mode to multi on the > RPS with > > request-redundant-power-system multi-backup > But first how about disconnecting all but one cable from the RPS. What is > the condition of LEDs? > > I assume you have done at least one commit on each switch? > > > On Jul 4, 2013, at 11:38 AM, Nick Kritsky <[email protected]> wrote: > > Jerry, > > Most annoying thing - it does not provide redundant power to the switches. > I could live with other problems, but this one is kind of a deal breaker. > I have all 3 AC PS inserted. I have 4 DC outlets connected to 4 EX3300 > switches. I have console port on RPS connected to console server and I can > get access to some crippled shell inside it. > when I issue command "show chassis redundant-power-system" on the switch > with DC connected to RPS, I got following answer: > "error: No RPS connected (chassis-control)" > > nick > > > On Thu, Jul 4, 2013 at 7:58 PM, Jerry Jones <[email protected]> wrote: > >> Only gotcha I have heard of is to use the center slot for the first power >> supply. >> >> What specifically is it not doing? >> >> >> On Jul 4, 2013, at 9:04 AM, Nick Kritsky <[email protected]> wrote: >> >> Hello all, >> >> Is anyone here who has experience with EX-RPS - redundant power supply for >> EX switches? >> I'd like to ask some questions/directions . >> >> From what I see - basically they are just DC converters with some minimal >> set of knobs. >> Documentation is virtually non-existent. Main idea I got from the site - >> it >> should just work when you plug it in. But guess what - it doesn't. It >> looks like I have missed some very simple step. The one that was >> considered >> obvious to the guy who was creating the manual :) >> >> thanks >> nick >> _______________________________________________ >> juniper-nsp mailing list [email protected] >> https://puck.nether.net/mailman/listinfo/juniper-nsp >> >> > > _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp