Couple ideas to try. You say switches have internal DC power so I guess there is no POE. If so then when you get a switch up I would suggest setting mode to multi on the RPS with request-redundant-power-system multi-backup
But first how about disconnecting all but one cable from the RPS. What is the condition of LEDs? I assume you have done at least one commit on each switch? On Jul 4, 2013, at 11:38 AM, Nick Kritsky <[email protected]> wrote: Jerry, Most annoying thing - it does not provide redundant power to the switches. I could live with other problems, but this one is kind of a deal breaker. I have all 3 AC PS inserted. I have 4 DC outlets connected to 4 EX3300 switches. I have console port on RPS connected to console server and I can get access to some crippled shell inside it. when I issue command "show chassis redundant-power-system" on the switch with DC connected to RPS, I got following answer: "error: No RPS connected (chassis-control)" nick On Thu, Jul 4, 2013 at 7:58 PM, Jerry Jones <[email protected]> wrote: Only gotcha I have heard of is to use the center slot for the first power supply. What specifically is it not doing? On Jul 4, 2013, at 9:04 AM, Nick Kritsky <[email protected]> wrote: Hello all, Is anyone here who has experience with EX-RPS - redundant power supply for EX switches? I'd like to ask some questions/directions . >From what I see - basically they are just DC converters with some minimal set of knobs. Documentation is virtually non-existent. Main idea I got from the site - it should just work when you plug it in. But guess what - it doesn't. It looks like I have missed some very simple step. The one that was considered obvious to the guy who was creating the manual :) thanks nick _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp _______________________________________________ juniper-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/juniper-nsp