Hi,
Thanks for your reply. Yeah. Those errType came from settings of clearance. 
Like a threshold value check. But I think that this clearance check can be 
relevantly according to different rules purposes. A different errTypes are in a 
result by different clearance settings. Hope Kicad wishlist have such this.
Thanks,
-Adam

--- In [email protected], Andy Eskelson <andyya...@...> wrote:
>
> 
> The errors tell you what the problems are, basically they are clearance
> issues. This can happen during layout if your bends in the tracks cut
> across a pad and "clip" the clearance area. The same thing applies to the
> zones, it's just too close to something. 
> 
> The co-ords in the error message will identify the location on the board
> where the problems are.
> 
> The first thing to do is fix the errors. How you do that will depend on
> the layout, usually I find that it just needs a slight tweak of the track
> position. Other times a reduction in track width might do the job, and
> so on.
> 
> 
> 
> 
> Andy
> 
> 
> On Mon, 04 Jan 2010 08:22:33 -0000
> "carouse9" <cl.adamw...@...> wrote:
> 
> > 
> > 
> > Hi
> > 
> > --- In [email protected], "fuzzyviv" <fuzzyviv@> wrote:
> > >
> > > 
> > > 
> > > But be sure to check your gerbers and drill files in either gerbv on 
> > > linux, or any gerber viewer in windows before sending.
> > > Specially drill files.
> > > I used the following settings for drill file dialog and it works-
> > > 
> > > suppress leading zeros
> > > precision 2:4
> > > origin - absolute 
> > > minimal header yes
> > > mirror y axis - no
> > > 
> > Hi,
> > 
> > We are doing a project [1]. After Pcb Design Rules Check in PCBnew, I got 
> > two kinds of err, type 19[2] and type 23[3]. Do you think that those err 
> > are serious? From them, I am assuming they are detected because of 
> > judgement from kicad default settings.
> > 
> > Also I followed and made settings as [4] and tried to create drill file[5], 
> > then I used a popular windows CAM gerber viewer to check it but I got err 
> > [6], do you think this is not caused by any potential errs we didn't know?
> > Thanks
> > Adam
> > 
> > [1] http://projects.qi-hardware.com/index.php/p/board-qi-avt2/
> > [2] 
> > http://downloads.qi-hardware.com/hardware/qi_avt2/RC2/report/layout_note/20100104/drc_control_errtype19.jpg
> > [3] 
> > http://downloads.qi-hardware.com/hardware/qi_avt2/RC2/report/layout_note/20100104/drc_control_errtype23.jpg
> > [4] 
> > http://downloads.qi-hardware.com/hardware/qi_avt2/RC2/report/layout_note/20100104/drill_files_generation.jpg
> > [5] 
> > http://downloads.qi-hardware.com/hardware/qi_avt2/RC2/report/layout_note/20100104/Qi_AVT2.drl
> > [6] 
> > http://downloads.qi-hardware.com/hardware/qi_avt2/RC2/report/layout_note/20100104/DRLREAD.ERR
> > 
> > 
> > 
> > ------------------------------------
> > 
> > Please read the Kicad FAQ in the group files section before posting your 
> > question.
> > Please post your bug reports here. They will be picked up by the creator of 
> > Kicad.
> > Please visit http://www.kicadlib.org for details of how to contribute your 
> > symbols/modules to the kicad library.
> > For building Kicad from source and other development questions visit the 
> > kicad-devel group at http://groups.yahoo.com/group/kicad-develYahoo! Groups 
> > Links
> > 
> > 
> >
>


Reply via email to