On Wednesday, 02/18/2004 at 05:07 EST, Aria Bamdad
<[EMAIL PROTECTED]> wrote:
> I have seen this message before also.  In most cases, I had defined the
> addresses without the 0x prefix or somehow wrong.
>
> Another situation where I saw this message is on a mult port OSA card
where
> you had to specify the adapter number (not always 0).  So, if your OSA
card
> has more than one adapter, you have to specify 1 or 2.

Make that "0 or 1".  There is no port 2.

Such an error might also occur if the card has not been reset since the
cables were plugged in.  OSA only detects cables at POR or chpid reset.