>>> On Tue, Jul 24, 2007 at  5:31 PM, in message
<[EMAIL PROTECTED]>, "Kandi, Santosh"
<[EMAIL PROTECTED]> wrote: 
> Mark,
> 
> The manual did not have a redirect(">") symbol and also did not instruct

You're right.  Brad?

--- s2-s390info-qeth.html.orig  2007-07-24 20:19:10.000000000 -0400
+++ s2-s390info-qeth.html       2007-07-24 20:20:31.000000000 -0400
@@ -89,7 +89,7 @@
       <p>
                                Next, bring the device back online:
                        </p>
-      <pre class="screen"># echo 1 
/sys/bus/ccwgroup/drivers/qeth/0.0.0600/online</pre>
+      <pre class="screen"># echo 1 &gt; 
/sys/bus/ccwgroup/drivers/qeth/0.0.0600/online</pre>
       <p>
                                Then verify the state of the device:
                        </p>


> us to do "echo 1 > /sys/bus/ccwgroup/drivers/qeth/0.0.0700/layer2".

That's because that page wasn't talking about working with Layer 2 devices, 
just Layer 3.

> Once I did that we were able to bring up Layer2 NIC.

Glad we could help.


Mark Post

----------------------------------------------------------------------
For LINUX-390 subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: INFO LINUX-390 or visit
http://www.marist.edu/htbin/wlvindex?LINUX-390

Reply via email to