Yes , we took the easy way and turned the firewall off. No luck :( My current suspicions is that somewhere a config default value specify that if two interfaces, use one as current and the other as backup Haven't verified that one yet, for the moment I'm preparing to clone a new server in our ip zone to verify it doesn't work here as well. Thank's anyway :)
___________________________________________ Tore Agblad Volvo Information Technology Infrastructure Mainframe Design & Development, Linux servers Dept 4352 DA1S SE-405 08, Gothenburg Sweden Telephone: +46-31-3233569 E-mail: [email protected] http://www.volvo.com/volvoit/global/en-gb/ -----Original Message----- From: Linux on 390 Port [mailto:[email protected]] On Behalf Of Amir Glaser Sent: den 12 juli 2010 16:45 To: [email protected] Subject: Re: Strange problems adding network adapter no 2 (eth1) in SLES11 SP1 Hi, Have you tried looking in the local firewall definitions (via Yast -> Security -> firewall)? Sometimes SLES11 tends to stick the new interface in the "External Zone" and therefore SSH access is prohibited. Thanks, Amir Glaser CSL-WAVE Development MGR Tel: +972 9 9540470, ext. 105 www.csl-int.com Fax: +972 9 9541452 -----Original Message----- From: Linux on 390 Port [mailto:[email protected]] On Behalf Of Agblad Tore Sent: Monday, July 12, 2010 3:58 PM To: [email protected] Subject: Re: Strange problems adding network adapter no 2 (eth1) in SLES11 SP1 Hi again. I'm in contact with a network person here and is trying to explain what's it all about. He is somewaht confused and he says the problem is in VIO. Is there anybody else having had this problem and succeeded in explain what to do ? We have a SLES10 maxhine with three network adapters and that works fine, but that is not in the same zone. The firewall hardwre and software is the same but obviously something differ here. Can I add the MACID statement for the NICDEFs and try that ? Do I need to fix that VMLAN MACPREFIX, or make sure it is set? Hmm, I have to dig into some manuals here it seams.... Cordialement / Vriendelijke Groeten / Best Regards / Med Vänliga Hälsningar Tore Agblad Volvo Information Technology Infrastructure Mainframe Design & Development SE-405 08, Gothenburg Sweden E-mail: [email protected] http://www.volvo.com/volvoit/global/en-gb/ ________________________________________ ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390 ---------------------------------------------------------------------- For more information on Linux on System z, visit http://wiki.linuxvm.org/ ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390 ---------------------------------------------------------------------- For more information on Linux on System z, visit http://wiki.linuxvm.org/