Am 01.04.2011 11:27, schrieb Florian Haas:
> On 2011-04-01 10:49, Christoph Bartoschek wrote:
>> Am 01.04.2011 10:27, schrieb Andrew Beekhof:
>>> On Sat, Mar 26, 2011 at 12:10 AM, Lars Ellenberg
>>> <[email protected]>   wrote:
>>>> On Fri, Mar 25, 2011 at 06:18:07PM +0100, Christoph Bartoschek wrote:
>>>>> I am missing the state: running degraded or suboptimal.
>>>>
>>>> Yep, "degraded" is not a state available for pacemaker.
>>>> Pacemaker cannot do much about "suboptimal".
>>>
>>> I wonder what it would take to change that.  I suspect either a
>>> crystal ball or way too much knowledge of drbd internals.
>>
>> The RA would be responsible to check this. For drbd any diskstate
>> different from UpToDate/UpToDate is suboptimal.
>
> Have you actually looked at the resource agent? It does already evaluate
> the disk state and adjusts the master preference accordingly. What else
> is there to do?

Maybe I misunderstood Andrew's comment. I read it this way:  If we 
introduce a new state "suboptimal", would it be hard to detect it?

I just wanted to express that detecting suboptimality seems not to be 
that hard.

Christoph
_______________________________________________
Linux-HA mailing list
[email protected]
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems

Reply via email to