righto - ran the multimeter across the cable. Those pinouts don't seem to match anything i found, but there does seem to be some resistors or something inline on a couple of wires which give odd readings to boot. *Shrug* Short of finding a replacement cable, i don't like my chances of trying to make another cable and then spending days chasing my tail around on the chance its not the cable anyway. I think I'll just but the M102 and its drive to bed for a while.
Thanks for everyone's help however. On Sun, Dec 24, 2017 at 4:19 PM, Brian White <[email protected]> wrote: > There was a schematic of the original cable somewhere but i can't find it. > You can try this one: > ftp://salsa.net/pub/M100SIG/Lib-09-PERIFERALS/TPDD.DO > The real cable has more active components in it than this, but the guy > claims it worked. > > > On Sat, Dec 23, 2017 at 10:29 PM, Mr Lurch <[email protected]> > wrote: > >> I actually woke up this morning thinking "I wonder if its just the cable?" >> Is there a wiring diagram for the cable anywhere? >> >> On Sun, Dec 24, 2017 at 3:12 AM, Fugu ME100 <[email protected]> wrote: >> >>> Hi >>> >>> The AO error means the COM port is already open for use so the IPL.BA >>> will fail when it tries to use it. Not sure why it should be open before >>> the IPL. I had similar sorts of issues with my old TPDD that I bought of >>> the well know auction site. It appeared never to have been used or perhaps >>> used once or twice. It came with everything including the Util Disk. I >>> did overhaul it with a new belt and made sure the internals were clean >>> before using it. >>> >>> I went through the following steps with my TPDD: >>> >>> 1) Cold Reset of the T102 to clear out the memory. Then try the IPL.BA >>> see if it functions any differently. It had been used to do other things >>> before I bought the drive. >>> >>> 2) Verify the Serial port on the T102 is OK. I did this on mine by >>> connecting it to a PC via a USB-Serial cable and running Coolterm (or other >>> serial program). If you then run the IPL.ba you should see the S1 record >>> appear on the Coolterm screen. Coolterm also shows the status of the CTS >>> and DSR lines to verify they work, they are needed by the TPDD drive. If >>> that checks out OK then the T102 is probably fine. You can also just open >>> TERM on the T102 and type text which should appear on Coolterm and >>> vice-versa. Mine verified OK in this step…. >>> >>> 3) Test out the cable by checking pin to pin connectivity and that there >>> a no bad lines. Turned out this was my problem and I suspect the reason why >>> the unit appeared never to have been used. One of the pins was >>> intermittent. After I fixed this problem everything seemed to work. >>> >>> 4) This step is new and I did not try it but appears useful in this >>> context to verify the TPDD is working. It should/might be possible to use >>> this program on a PC http://www.club100.org/memf >>> iles/index.php?&direction=&order=&directory=Kurt%20McCullum/ >>> TPDD%20Client to read the disk on the TPDD to make sure the serial >>> port on the drive is working it will also verify the cable is OK. The >>> program states for use with TPDD2 not sure if it will work with the TPDD >>> drive. It is not my program but might be worth looking at to verify the >>> drive is working. >>> >>> After I had Coolterm working I started to use mcomm and did not use the >>> TPDD again once I had seen Floppy.co :) >>> >>> From: M100 <[email protected]> on behalf of Mr Lurch < >>> [email protected]> >>> Reply-To: <[email protected]> >>> Date: Saturday, December 23, 2017 at 12:17 AM >>> To: <[email protected]> >>> Subject: [M100] TPDD1 help? >>> >>> Evening all, >>> So I managed to get a copy of the proper utility disk (thanks Gordon!) - >>> but still no joy. >>> I've created the IPL.BA >>> <https://eur01.safelinks.protection.outlook.com/?url=http%3A%2F%2FIPL.BA&data=02%7C01%7C%7C2bfd8d13b48542bb845a08d549ddacca%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C636496138788243218&sdata=5Og33kHo9JOwWZ6tP75td8g84nRVo9nYm%2Bck9pkRgv4%3D&reserved=0> >>> file (and triple checked my inputs). Running it does the following >>> (everytime) >>> First run: AO error. >>> Go back to Menu. >>> Run it again. Screen goes blank, disk reads for a split second, then >>> nothing. >>> Thats all she wrote. >>> >>> Initially, on the second run, the disk would read for a split second and >>> then the battery LED would flash continuously. Like I hadnt set the DIP >>> switches to On (which I had). I gave the switch bank a spray with contact >>> cleaner and moved them back and forth a bunch of times. That *seemed* to >>> fix the flashing battery light, and thats where im at now. >>> >>> Not sure if this is related, but if I switch on the drive first, and >>> then the M102, the battery light flashes continuously until I switch off/on >>> the drive again. >>> >>> - Jase >>> >>> >> >