interesting experiment, but after reading the datasheet I don't think 1x
mode is usable in T200 in general.  It assumes that the clock and data are
phase aligned, whereas in 16x mode the UART counts 8 pulses to find middle
of the eye.

However 38400 should be doable in 16x mode.

On Sat, Jun 2, 2018 at 5:41 PM, John R. Hogerhuis <[email protected]> wrote:

>
> On Sat, Jun 2, 2018 at 1:35 PM Stephen Adolph <[email protected]>
> wrote:
>
>> success!  for the most part this yields clean transmission. From time to
>> time I think there is a buffer overrun due to BASIC being slow.   or maybe
>> the link corrupts, don't know yet.  It might lose sync.
>>
>> T200 ---> T200 @76800
>>
>> source:
>> 10 open "COM:78n1enn" for output as 1  : REM make port look like 4800
>> 20 out 207,64 :REM reset the uart
>> 30 out 207,77 : REM async x1 mode 8 n 1, boost port by 16 x to 76800
>> 40 out 207,37 : REM turn on the interface
>> 50 print#1,"this is a test":goto50
>>
>> destination
>> 10 open "COM:78n1enn" for input as 1
>> 20 out 207,64
>> 30 out 207,77
>> 40 out 207,37
>> 50 input#1,a$:print a$:goto50
>>
>>
>> T
>>
>>
> Yeah I can’t remember whether it failed altogether or it just wasn’t
> reliable.
>
> I can try it in HTERM.
>
> — John.
>
>>
>>