interesting experiment, but after reading the datasheet I don't think 1x mode is usable in T200 in general. It assumes that the clock and data are phase aligned, whereas in 16x mode the UART counts 8 pulses to find middle of the eye.
However 38400 should be doable in 16x mode. On Sat, Jun 2, 2018 at 5:41 PM, John R. Hogerhuis <[email protected]> wrote: > > On Sat, Jun 2, 2018 at 1:35 PM Stephen Adolph <[email protected]> > wrote: > >> success! for the most part this yields clean transmission. From time to >> time I think there is a buffer overrun due to BASIC being slow. or maybe >> the link corrupts, don't know yet. It might lose sync. >> >> T200 ---> T200 @76800 >> >> source: >> 10 open "COM:78n1enn" for output as 1 : REM make port look like 4800 >> 20 out 207,64 :REM reset the uart >> 30 out 207,77 : REM async x1 mode 8 n 1, boost port by 16 x to 76800 >> 40 out 207,37 : REM turn on the interface >> 50 print#1,"this is a test":goto50 >> >> destination >> 10 open "COM:78n1enn" for input as 1 >> 20 out 207,64 >> 30 out 207,77 >> 40 out 207,37 >> 50 input#1,a$:print a$:goto50 >> >> >> T >> >> > Yeah I can’t remember whether it failed altogether or it just wasn’t > reliable. > > I can try it in HTERM. > > — John. > >> >>