there will be escape characters flowing over serial in this case, so you
need to ensure that does not mess with things.
If I understand what is happening

M100 ---->   PC  (video terminal character flow)
M100 <----  PC  (input keyboard strokes)

When you say the terminal works reliably using F3, you are using the PC as
a display for CP/M, right?  And in this case, you selected VT100 emulation?




On Tue, Nov 16, 2021 at 5:05 PM Tom Hoppe <[email protected]> wrote:

> I left minicom set to 19200 8N1 and it worked (until it didn't). The Sc L
> vs Sc S is a good point! I will try changing this tonight and see if
> it helps. My ultimate goal is to ssh into my home PC from work so I can
> play with CP/M during lunch :).
>
> Tom
>
>
> On Tue, Nov 16, 2021 at 11:21 AM Jim Anderson <[email protected]> wrote:
>
>> First thought that comes to mind: it may be stopping because of the
>> feature which pauses the screen output after 8 lines of consecutive output
>> – try Label-F1-Label to toggle ‘Sc L’ to ‘Sc S’ to disable this before
>> redirecting the console?
>>
>>
>>
>> I’m glad to see this post because I honestly had been thinking a while
>> back that “I wish there was a way to use a ps/2 keyboard with my MVT100
>> board as a full-blown terminal” but didn’t try anything because I’m not
>> familiar enough with CP/M to know how to redirect the console like that.
>> What baud rate does it end up using when you do this?
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>
>>         jim
>>
>>
>>
>> *From:* M100 <[email protected]> *On Behalf Of *Tom Hoppe
>> *Sent:* Tuesday, November 16, 2021 10:50
>> *To:* [email protected]
>> *Subject:* [M100] Re-directing CP/M console to serial port in REXCPM
>>
>>
>>
>> *CAUTION External Sender:* Do not click links or open attachments unless
>> you recognize the sender and know the content is safe.
>>
>>
>>
>> I am trying to re-direct the REXCPM console to the M100 serial port but
>> only having limited success. I am using 'stat con:=uc1:' to do the
>> re-direct. It seems to work for a minute, then stops. I am using minicom in
>> Linux and it works reliably using the REXCPM 'F3 toggle' feature to
>> re-direct only the screen output (19200 8N1). Has anyone else tried doing
>> this successfully?
>>
>>
>>
>> Tom Hoppe
>>
>>
>>
>>

Reply via email to