Is there an orifice tube at the condenser?  I think the blockage there or at
the receiver/dryer would explain the lack of refrigerant flow visible at the
sight glass.

I guess I'm going to have to open it up and flush the evaporator and
condenser and then see if it will hold a vacuum.

-Max

-----Original Message-----
From: mercedes-boun...@okiebenz.com [mailto:mercedes-boun...@okiebenz.com]
On Behalf Of Jim Cathey
Sent: Thursday, February 24, 2011 8:25 PM
To: Mercedes Discussion List
Subject: Re: [MBZ] (SPAM?) 124 AC woe

> Now I have proper gauge
> reading on high side but still vacuum on suction side, when it should 
> be about
> 15 to 20 psi...so I've got a blockage somewhere.

If you did have a blockage, and anything like a normal charge
in there, you would have excessive high-side pressures to go
with excessively-low low-side pressures.

-- Jim