Thanks It does explain the symptoms Seems most likely a leaking vacuum pod.will check it , mostly behind the centre panel
mak

My guess is that one of the pods has a vacuum leak, and when the
ACC goes to actuate it the vacuum leaks away and the system defaults
to the defrost vent pattern.  Maybe the footwell pod?  Use a MityVac
on the lines coming out of the electric vacuum manifold behind the
ACC panel.  (Or is it behind the glove box?)

-- Jim


_______________________________________
http://www.okiebenz.com
For new parts see official list sponsor: http://www.buymbparts.com/
For used parts email [EMAIL PROTECTED]

To Unsubscribe or change delivery options go to:
http://okiebenz.com/mailman/listinfo/mercedes_okiebenz.com



--
No virus found in this incoming message.
Checked by AVG Free Edition.
Version: 7.1.394 / Virus Database: 268.9.2/370 - Release Date: 6/20/2006



Reply via email to