On Thursday 05 February 2009 03:16:52 Brian Johnson wrote: > I think the issue with the mt9v112 has to do with the fact that that > sensor has an active window of only 640x480 pixels where as the sensor > on your camera has an active array of 1280x1024 pixels try mosifing > the register writes for regissters 1-4 to adjust the size of the > window inparticulare you can likely get rid of the black area by > modifiering registers 1 and 2 whcih are the x and y start postions for > your window registers 3 and 4 give it the wifth and height.
Right! Modifying 1 & 2 registers I removed the black spaces. Tell me please, what width&height we're dealing with? Is it an order to sensor to read only windowed part of it's matrix? Or an order to stream the video data at this resolution? When I set 3&4 at max res of 1280x1024 the framerate decreases to the half (and this is described in specs), but again, I see only part of the image comparing to the M setup. So I want to get the image from the whole res of sensor and then stream in in VGA :) --~--~---------~--~----~------------~-------~--~----~ Lets make microdia webcams plug'n play, (currently plug'n pray) To post to this group, send email to [email protected] Visit us online https://groups.google.com/group/microdia -~----------~----~----~----~------~----~------~--~---