Hi at all MITK Diffusion user,

I need to do some IVIM analysis, but I'm blocked with dicom import.

I tried to run the command Import DICOM as *.dwi but, although MITK says 
"Finished import", I don't found any *.dwi file.

The log is this:

== Initial Directory Scan ==
...found 10 different files
Scanning Headers
...succesfully scanned 5 headers
Sorting
Number of files in series not equal, Some volumes are probably 
incomplete. ABORTING

My scanner is and Ingenia 1.5 T (by now i don't remeber software 
version). I know there are some problems with Philips dicom.

How can i resolve this problem?

Do you have any suggestion?

Thanks in advance and Best Regards.

Nicolò Cardobi

P.s.: I tried dicom to nrrd conversion with slicer with no luck.

------------------------------------------------------------------------------