At 05:15 PM 9/2/99 +0200, you wrote:

>To reset a interrupt from a horizontal line interrupt (reg #19), I used
>to set the interupt enable bit to zero and then back on again. Turning
>the bit off also dropped the interrupt.
>This was better because I could now make the interupt line drop in
>lesser time, I just had two write twice to a register. With the official
>read methode I had to write a register, wait, read a status register and
>then put #15 back to zero (as assumed by the standard interrupt handler)

Nice trick! I didn't know it.

The fact that this trick works also tells something about the internal
workings of the VDP. I expect Frits can use this info for perfecting NLMSX.

Bye,
                Maarten


****
MSX Mailinglist. To unsubscribe, send an email to [EMAIL PROTECTED] and put
in the body (not subject) "unsubscribe msx [EMAIL PROTECTED]" (without the
quotes :-) Problems? contact [EMAIL PROTECTED] (www.stack.nl/~wiebe/mailinglist/)
****