Le 13 mai 2011 12:23, Jean-Michel Pouré - GOOZE <[email protected]> a écrit : > I read libccid code again and you seem to assume that if the reader > rates are not announced and maximum rate is superior to card rate, we > may use card rate. libccid current code is trivial.
The problem is that the Feitian reader is "bogus" and announces rates but only ONE rate is announced: 10752 bauds See http://pcsclite.alioth.debian.org/ccid/readers/Feitian_SCR310.txt One easy solution is to fix the reader firmware to either report no rate at all or report all the supported rates. Bye -- Dr. Ludovic Rousseau _______________________________________________ Muscle mailing list [email protected] http://lists.drizzle.com/mailman/listinfo/muscle