Le 13 mai 2011 12:23, Jean-Michel Pouré - GOOZE <[email protected]> a écrit :
> I read libccid code again and you seem to assume that if the reader
> rates are not announced and maximum rate is superior to card rate, we
> may use card rate. libccid current code is trivial.

The problem is that the Feitian reader is "bogus" and announces rates
but only ONE rate is announced: 10752 bauds
See http://pcsclite.alioth.debian.org/ccid/readers/Feitian_SCR310.txt

One easy solution is to fix the reader firmware to either report no
rate at all or report all the supported rates.

Bye

-- 
 Dr. Ludovic Rousseau

_______________________________________________
Muscle mailing list
[email protected]
http://lists.drizzle.com/mailman/listinfo/muscle

Reply via email to