Hello,

here the connections (I have got it from Mike and removed one
error...):

Bottom Connector (left-to-right, viewed from rear):
1 - Filaments, 6.3V
2 - Filaments, 6.3V
3 - B+ Supply, 300V
4 - BD Tube Clear (0.001uf cap coupling to BD-301 cathode)
5 - Input (50-60V negative pulse, rising edge <1usec)
6 - Cascade Output
7 - N/C
8 - Ground
9 - N/C
10 - BD Tube Reset (24pf cap coupling to BD-301 spade 9)

Top Connector (left-to-right, viewed from rear):
1 - Spade/Nixie Cathode 0
2 - Spade/Nixie Cathode 9
3 - Spade/Nixie Cathode 8
4 - Spade/Nixie Cathode 7
5 - Spade/Nixie Cathode 6
6 - Spade/Nixie Cathode 5
7 - Spade/Nixie Cathode 4
8 - Spade/Nixie Cathode 3
9 - Space/Nixie Cathode 2
10 - Spade/Nixie Cathode 1

I have not tested the reset yet, the tube simply starts counting in a
random position.

Regards,
René.

On 9 Okt., 14:35, Dekatron42 <[email protected]> wrote:
> Hi,
>
> Could you please post the schematic for yoru connections. If you have
> succesfully been able to drive the reset wiring giving correct resets
> I'd be interrested in that too.
>
> Regards

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To post to this group, send an email to [email protected].
To unsubscribe from this group, send email to 
[email protected].
For more options, visit this group at 
http://groups.google.com/group/neonixie-l?hl=en-GB.

Reply via email to