2007/7/26, Arjen de Korte <[EMAIL PROTECTED]>:
>
> [...]
>
> > Is the shutoff working otherwise (ie calling upsdrvctl -k (CAUTION: no
> > sensitive load on the UPS; only light bulbs or alike))?
>
> We have no '-k' option in upsdrvctl. The proper command to test this is
> either
>
> upsdrvctl shutdown <upsname>
>
>     or
>
> bcmxcp_usb -a <upsname> -k

uh, right. too many mails addressed too quickly...
thanks to Arjen for the proof reading ;-)

Arnaud
-- 
Free Software Developer - http://arnaud.quette.free.fr/
Debian Developer - http://people.debian.org/~aquette/