Power is supplied, 12V 1500mA. I dont have any other versions of DS18x20 but I have 4 of theese DS18S20-PAR and all of them returns the same result using OWFS. Using digitemp I get correct reading everytime. I have some relays using DS2405 and they works gret in OWFS and they are connected thru the same switch or was, now disconnected caus I wanted to eleminate any disturbance on the 1wire bus.
/Thomas Mark Richards skrev: > Thomas Berg wrote: >> Ds18S20 is connected between pin 1 and pin 3. >> I have moved it to the main port. > I'm entering a "stumped" state. > Same result both ports? >> >> Since I´m using DS18S20-PAR I don´t think it so good ide to supply pover >> to pin 3 since its internally connected to pin 1. > OK. Correct. Can you try a DS18B20 or DS18S20 to see if there's a > difference? >> >> I´m using the 6-channel master hub from hobby-boards >> (http://www.hobby-boards.com/catalog/product_info.php?cPath=23&products_id=33), >> >> and as I worte ealrier it work just fine with other software like >> igitemp so i doubt that there is an hardwareproblem. > I looked at the schematic and this looks to be a very generic design. > > I assume you've applied power. :) > > stupid question: Are you certain OWFS supports going through a switch? > Digitemp allows only a single level (one switch) to get to a sensor. > Maybe owfs doesn't even allow for this, or perhaps you've already > asked this question on the list? > > /m > > ------------------------------------------------------------------------- Take Surveys. Earn Cash. Influence the Future of IT Join SourceForge.net's Techsay panel and you'll get the chance to share your opinions on IT & business topics through brief surveys-and earn cash http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers