Power is supplied, 12V 1500mA. I dont have any other versions of DS18x20
but I have 4 of theese DS18S20-PAR and all of them returns the same
result using OWFS. Using digitemp I get correct reading everytime. I
have some relays using DS2405 and they works gret in OWFS and they are
connected thru the same switch or was, now disconnected caus I wanted to
eleminate any disturbance on the 1wire bus.

/Thomas

Mark Richards skrev:
> Thomas Berg wrote:
>> Ds18S20 is connected between pin 1 and pin 3.
>> I have moved it to the main port.
> I'm entering a "stumped" state.
> Same result both ports?
>>
>> Since I´m using DS18S20-PAR I don´t think it so good ide to supply pover
>> to pin 3 since its internally connected to pin 1.
> OK.  Correct.  Can you try a DS18B20 or DS18S20 to see if there's a
> difference?
>>
>> I´m using the 6-channel master hub from hobby-boards
>> (http://www.hobby-boards.com/catalog/product_info.php?cPath=23&products_id=33),
>>
>> and as I worte ealrier it work just fine with other software like
>> igitemp so i doubt that there is an hardwareproblem.
> I looked at the schematic and this looks to be a very generic design.
>
> I assume you've applied power. :)
>
> stupid question: Are you certain OWFS supports going through a switch?
> Digitemp allows only a single level (one switch) to get to a sensor.
> Maybe owfs doesn't even allow for this, or perhaps you've already
> asked this question on the list?
>
> /m
>
>


-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys-and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
Owfs-developers mailing list
Owfs-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to