BTW: Replacing DTR with Vcc(+resistance) doesn't work as I suggested. DTR should be between -3 -- -15 when the rs232-port is open and ready. This means that you have to use one max3232 pin for converting the Vcc to the negative signal which is a logical "1".
/Christian > -----Original Message----- > From: [EMAIL PROTECTED] [mailto:owfs- > [EMAIL PROTECTED] On Behalf Of suman- > Sent: den 16 september 2007 06:15 > To: owfs-developers@lists.sourceforge.net > Subject: Re: [Owfs-developers] MIPS vs MIPSEL in OWFS > > > > Yes, Christian, serial interface in my AP is in TTL level, where I can > use > MAX3232 with DS9097 (or DS2480 directly as pointed out by njh) for > 12v-to-3.3v conversion. Thanks for your (and njh's) useful information > ... I > will try out these hacks soon! > > But ... before trying it on AP, I tried it on my PC if I can pull out > any > information, which I failed. > ------------------------------------------------------------------------- This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2005. http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers