Hi,
We start to name the layers from the top layer downwards as layer1, layer2,
layer3..... the non conductive layers are named as they are intended, that
is overlay as top/bottom silkscreen, mechanical. In our case we use GBR
extension for the Gerber files. Also, we practice to put the same
information on the respective layers either in +ve image or -ve image [text
not overlapping each other] preferably on the bottom left corner readable
from layer1, inside the PCB.

We aslo include a file that defines the other charecteristics of the PCB
like material, dimension, file name, stackup, etc along with contact
information.

This has enabled us to use multiple vendors to fabricate our PCBs.

Thanks & Regards
Jeyaraman
Senior Research Engineer
[EMAIL PROTECTED]

The information transmitted is intended only for the person or entity to
which it is addressed and may contain confidential and/or privileged
material. Any review, retransmission, dissemination or other use of, or
taking of any action on reliance upon, this information by persons or
entities other than the intended recipient is prohibited. If you received
this in error, please contact the sender and delete the material from any
computer.
----- Original Message ----- 
From: "Adeel Malik" <[EMAIL PROTECTED]>
To: <[email protected]>
Sent: Monday, February 07, 2005 9:34 PM
Subject: [PEDA] Protel Gerber File Extensions,Are they conform to Standard
Industry Practice ???


Hi All,
            My PCB vendor asks me that in order to correctly ascertain
about the identity of Top Layer and Bottom Layer, I should manually
write the string "TOP" in the Top Copper Layer and string "BOTTOM" in
the Bottom Copper Layer.
I tell him that this information is embedded in the Gerber File
extensions itself. e.g Design.GTL and Design.GBL means that these files
correspond to Top Copper and Bottom Copper Layers respectively.

I wanna ask whether this naming of Gerber file extensions by Protel
conforms to standard Industry Practice or not ?. If yes, can someone
comment about the legitimacy of my PCB Vendor's opinion that I need to
mention the layer name in text manually. ?....

Regards,
Adeel Malik.

____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]

Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]


 
____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]
 
Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]

Reply via email to