Do any of the build farm machines not support 64-bit integers? I just added a
--enable-bigint flag to configure.in and tested building without it and got an
error at xlog.c:

xlog.c: In function 'ValidXLOGHeader':
xlog.c:3240: error: 'UINT64_FORMAT' undeclared (first use in this function)
xlog.c:3240: error: (Each undeclared identifier is reported only once
xlog.c:3240: error: for each function it appears in.)

        snprintf(fhdrident_str, sizeof(fhdrident_str), UINT64_FORMAT,
                         longhdr->xlp_sysid);
        snprintf(sysident_str, sizeof(sysident_str), UINT64_FORMAT,
                         ControlFile->system_identifier);

It's possible I've done the autoconf hackery wrong though. Should
UINT64_FORMAT still be defined if there's no int64?

-- 
  Gregory Stark
  EnterpriseDB          http://www.enterprisedb.com


---------------------------(end of broadcast)---------------------------
TIP 4: Have you searched our list archives?

               http://archives.postgresql.org