Great, thanks
But now I have another problem. Since runsync is running as a sceduled event
(non interactive) I
cannot see any error messages it produces. Sometimes it gives a message
about a corrupt jpeg file
in the cache direcory, and a "press any key to continue" message.
I now have runsync scheduled to run every hour througout the day. This
morning when I came
to work there were 5 runsync processes and 5 phyton processes running. I
assume they were
stuck at the "press any key...." message.
I've specified verbosity=0 in plucker.ini. Is there a way to disable this
"press any key" stuff ?
---
P�l Andreassen
[EMAIL PROTECTED]
23 15 79 65 (direct)
970 36 930 (mobile)
> -----Original Message-----
> From: Dirk Heiser [mailto:[EMAIL PROTECTED]]
> Sent: Tuesday, May 29, 2001 4:29 PM
> To: Plucker List
> Subject: Re: running plucker as a scheduled tast (windows 2000)
>
>
> "P�l" == P�l Andreassen <[EMAIL PROTECTED]> writes:
>
> P�l> sites and create the .pdb file so I was hoping I could set this
> P�l> up as a task using Windows 2000 task manager (at from the command
> P�l> prompt). This way I can have plucker running on idle priority
> P�l> once every hour or so. Then when I hotsync I know that my Plucker
> P�l> data never is more than one hour old.
>
> P�l> specifying something like:
> P�l> at 11:00 /every:m,t,w,th,f "runsync defult"
>
> Yes, Call:
> C:\Program Files\Plucker\RunSync.exe Default
> ^^^^^^^^^^^^^^
> Whatever you pathes here
>
> And it should work.
>
>
> P�l> to set the scheduler up. At 11:00 plucker starts
> gathering it's files, but
> P�l> at the end the conduit complains about errors and an incomplete
> ^^^^^^^^^^^^^^^^^^^^^^^^
>
> Reading the Full message help in most cases :-) I guess it was:
>
> "The Palm Desktop software is not correctly installed."
> ^^^^^^^^^^^^^^^^^^^^^^^^^
>
> P�l> installation. Running runsync my self always works fine.
> What is the purpose
>
> You are logged in as USER? Does the Palm Install Tool work at this
> time?
>
> P�l> of the conduit ? All that is needed after the creation
> of the .pdb file is
> P�l> to copy it to
> P�l> %palmhome%\%username%\install\
>
> No that's no enough. there need also a registry setting to inform the
> HotSync that a file need installed.
>
> P�l> The error results in a messagebox beeing displayed in
> Windows, the box
> P�l> itselv is invisible unless i run the tasks as /interactive.
>
> P�l> I've tried to scecify use_conduit=0 in plucker.ini and
> do the copying using
> P�l> a script, but that did'nt seem to work.
>
> I guess the Problem is that you specify a user (user=) in plucker.ini,
> so the software try to prepare this file to install, but this fail
> because, in the logged in user/admin, the Palm Desktop registry
> settings are missing.
>
> So delete the user key in plucker.ini and the Software no longer try
> to install the file.
> If you wan't that the file are copy to another location after
> creation, see the after_command ini key.
>
> HTH,
> Dirk
>
> --
> Permanent URLs to the latest Version () of the Plucker
> Windows installer
> - For the Webpage: http://www.dirk-heiser.de/plucker
> - Direct Download:
> http://www.dirk-heiser.de/plucker/plucker.exe [2.79MB]
>