Thank you for your kind words Sunnysekot.  Your amp sounds very strange!
Some ir protocols do indeed specify that a commend needs to be sent a
certain number of times before it is recognised, but RC5 isn't one of
them. Even stranger is that it's a Philips amp and Philips invented RC5
so if anything was going to follow the spec I would expect it to be
their own kit.

The '+' uses the protocol's actual repeat timing (113 ms for RC5) and
is what I would expect people to use when only sending one command.
Without the '+' the command is sent every 200ms (an arbitrary number
used to space out sequential codes and long enough to ensure they don't
overlap).

What model is your amp? If there's a LIRC file for it I may be able to
decipher it and tell you what codes to use for on/off.


-- 