The Duke fleet has an in-house radiography group.  They may supplement with 
contractors and are responsible for all aspects of their time from arrival on 
site through out-processing.

RP is heavily involved in all aspects of the radiography operation.  RP 
Supervision reviews boundary maps, walks down the area, and determines search 
criteria. RP helps prepare the pre-job brief. RP Supervision conducts the 
pre-job with RT. RP must concur with the source retraction verification method. 
 RP Management verifies (IV) the boundary. RP also participates in the search.  
RP then provides oversight during the shot itself.  RP has a lock on the source 
cabinet.

Tim O'Donohue
980-373-7998



From: [email protected] [mailto:[email protected]] On Behalf Of 
Huneycutt, Scott
Sent: Wednesday, August 25, 2010 1:03 PM
To: '[email protected]'
Cc: Huneycutt, Scott; Hopkins, John (MT)
Subject: Powernet: Oversight of Radiography operations

Monticello would like ask how other facilities supervise or control radiography 
operations.

Who, or what group, is responsible for the control of radiographers at your 
station (e.g. coordinating their arrival on-site, ensuring training is done, 
responsible for work order preparation, etc.)? Is RP responsible for this?

Is RP only responsible during radiography operations? (e.g. verify boundaries, 
prohibiting access to area, etc.)
Thank you,
Scott Huneycutt
Xcel Energy | Responsible By Nature
Health Physicist
Monticello Nuclear Generating Plant
2807 West County Road 75, Monticello, MN 55362
P: 763.295.1380   F:  763.295.1225
E: [email protected]<mailto:[email protected]>
________________________________________________
XCELENERGY.COM<http://www.xcelenergy.com/>
Please consider the environment before printing this email