Engineering owns this but RP is involved in all aspects of the
radiography operation. Too much to list but we have procedures that
drive us to develop Alara Plans etc. The procedure also includes RPSS
in field, walk downs verifying area is free of personnel, approvals
prior to starting etc. Engineering is also responsible to provide us
with information such as location, component, and source data.
Harry L. Miller
Exelon
Nuclear
Braidwood Station
Radiological Engineer
* Telephone: 815.417.2713
* Email: [email protected]
* Fax: 815.417.4210
On-site pager: 815.417.2713
Off-site pager: 815.767.0679
________________________________
From: [email protected] [mailto:[email protected]] On Behalf
Of O'Donohue, Timothy W
Sent: Wednesday, August 25, 2010 12:36 PM
To: [email protected]
Subject: Powernet: RE: Oversight of Radiography operations
The Duke fleet has an in-house radiography group. They may supplement
with contractors and are responsible for all aspects of their time from
arrival on site through out-processing.
RP is heavily involved in all aspects of the radiography operation. RP
Supervision reviews boundary maps, walks down the area, and determines
search criteria. RP helps prepare the pre-job brief. RP Supervision
conducts the pre-job with RT. RP must concur with the source retraction
verification method. RP Management verifies (IV) the boundary. RP also
participates in the search. RP then provides oversight during the shot
itself. RP has a lock on the source cabinet.
Tim O'Donohue
980-373-7998
From: [email protected] [mailto:[email protected]] On Behalf
Of Huneycutt, Scott
Sent: Wednesday, August 25, 2010 1:03 PM
To: '[email protected]'
Cc: Huneycutt, Scott; Hopkins, John (MT)
Subject: Powernet: Oversight of Radiography operations
Monticello would like ask how other facilities supervise or control
radiography operations.
Who, or what group, is responsible for the control of radiographers at
your station (e.g. coordinating their arrival on-site, ensuring training
is done, responsible for work order preparation, etc.)? Is RP
responsible for this?
Is RP only responsible during radiography operations? (e.g. verify
boundaries, prohibiting access to area, etc.)
Thank you,
Scott Huneycutt
Xcel Energy | Responsible By Nature
Health Physicist
Monticello Nuclear Generating Plant
2807 West County Road 75, Monticello, MN 55362
P: 763.295.1380 F: 763.295.1225
E: [email protected] <mailto:[email protected]>
________________________________________________
XCELENERGY.COM <http://www.xcelenergy.com/>
Please consider the environment before printing this email
-----------------------------------------
**************************************************
This e-mail and any of its attachments may contain Exelon
Corporation proprietary information, which is privileged,
confidential, or subject to copyright belonging to the Exelon
Corporation family of Companies.
This e-mail is intended solely for the use of the individual or
entity to which it is addressed. If you are not the intended
recipient of this e-mail, you are hereby notified that any
dissemination, distribution, copying, or action taken in relation
to the contents of and attachments to this e-mail is strictly
prohibited and may be unlawful. If you have received this e-mail
in error, please notify the sender immediately and permanently
delete the original and any copy of this e-mail and any printout.
Thank You.
**************************************************