1)      VC Summer Station uses impingers.


2)      Yes - determined using a series of impingers in a tritium atmosphere.


For additional questions, contact:
Mike Roberts
Health Physics Supervisor-Radiological Effluent and Environmental Monitoring
V. C. Summer Nuclear Station
W - 803-931-5708        C  - 803-608-3150

[cid:[email protected]]



From: [email protected] [mailto:[email protected]] On Behalf Of 
Johnson, Graham T
Sent: Thursday, August 26, 2010 9:41 AM
To: [email protected]
Subject: Powernet: Effluent Tritium sampling method

Duke Energy would appreciate your answers to the following questions about 
sampling for tritium in air in effluent (i.e. Unit Vent effluent sampling)


1)       What method do you use for sampling tritium in air? (bubble impinger, 
silica gel, cold trap, or other method)

2)      Have you documented the efficiency of the method used?

Thanks in advance for your response.

Graham Johnson, CHP
General Office RP
Duke Energy

<<inline: image001.gif>>