We purchased (10 ASP-2 with 380B probes) for frisking large items to be
released and 2 REM 500's for neutron characterization.


Access Control Normal for all traffic except SGR
4 SAM-11's
4 ARGOS (purchased with SGR money)
2 PM-7

SGR Access Control
4 SAM-11's (purchased with SGR money)
4 PCM-2's
2 PM-7

Decon Tent and RMC Access Control
2 SAM-11's
2 SAM-9S
1 PM-7 (purchased with SGR money)
2 PCM1B's

For RP coverage the basic
50 Ion chambers
8 Stretch Scopes
5 RO-7
40 Handheld friskers (Bicron Surv M)

Scott E. Bradley, CHP

Radiation Protection Manager



Office: 254-897-5495     Pager: 817-667-0659

Cell: 254-326-8145        Fax: 254-897-5869

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf
Of [email protected]
Sent: Tuesday, August 31, 2010 11:41 AM
To: [email protected]
Subject: Powernet: SGRP

I am interested in the types, models and quantities of instruments you
purchased to support a Stean Generagor Replacement Project and Head
Replacement Project.  If you have a list or information on quantities or
post replacement recomendations I would appreciate your input.  I am
creating a list and projected cost for DB, any info would be valuable.

Thank You,
June

June L. Scott
[email protected]
Phone: 419-321-8555
Cell:      419-367-6651
Davis Besse Nuclear Power Station
5501 N State Route 2
Oak Harbor, Oh 43449

-----------------------------------------
The information contained in this message is intended only for the
personal and confidential use of the recipient(s) named above. If
the reader of this message is not the intended recipient or an
agent responsible for delivering it to the intended recipient, you
are hereby notified that you have received this document in error
and that any review, dissemination, distribution, or copying of
this message is strictly prohibited. If you have received this
communication in error, please notify us immediately, and delete
the original message.
-----------------------------------
Powernet - a service of the Health Physics Society Power Reactor Section

Powernet archives at http://www.mail-archive.com/[email protected]/

Reply to: [email protected]
If Questions, contact Mike Russell, CHP at [email protected]


Confidentiality Notice: This email message, including any attachments, 
contains or may contain confidential information intended only for the 
addressee. If you are not an intended recipient of this message, be 
advised that any reading, dissemination, forwarding, printing, copying
or other use of this message or its attachments is strictly prohibited. If
you have received this message in error, please notify the sender 
immediately by reply message and delete this email message and any
attachments from your system.
-----------------------------------
Powernet - a service of the Health Physics Society Power Reactor Section

Powernet archives at http://www.mail-archive.com/[email protected]/

Reply to: [email protected]
If Questions, contact Mike Russell, CHP at [email protected]

Reply via email to