Salem Generating Station allows only Sr. HP(s) to use the SAM.

Alex Johns
RPS
Salem Generating Station
856-339-3909

________________________________
From: [email protected] [mailto:[email protected]] On Behalf Of 
[email protected]
Sent: Tuesday, November 08, 2011 3:48 PM
To: [email protected]
Subject: RE: Powernet: SAM-11 Operations

Palo Verde just recently implemented SAM-12 tool monitors and we have not 
experienced this situation (yet).  Prior to using the SAMs, we used tool 
monitors that relied on door operation to automatically start the counting 
cycle.  The described situation is an inherent feature of the SAMs and from a 
corrective action perspective you would be faced with prohibiting workers from 
using unless they had direct RP supervision or perhaps implementing an advanced 
radworker qualification to use a tool monitor.

I think that we will all be interested in this, Seth.


From: [email protected] [mailto:[email protected]] On Behalf Of 
[email protected]
Sent: Tuesday, November 08, 2011 1:38 PM
To: powernet@
Subject: Powernet: SAM-11 Operations

SONGS allows workers to monitor personal articles in SAM-9 and SAM-11 tool 
monitors under limited supervision by HP.   We have had occasions where workers 
place material in the monitors, and do not push the start button, or place 
items in the SAM during a background count.  While an attentive worker can 
observe fault messages, it appears the messages from the SAM-11 are less 
distinct than those produced by the SAM-9.  Some workers have passed items 
through SAM-11s without an actual count.


Does anyone else have similar experiences?  How have you responded?


Roger Schanzenbach
HP Technical Support
San Onofre Nuclear Generating Station
(949) 368-9580







----------------------------------- Powernet - a service of the Health Physics 
Society Power Reactor Section Powernet archives at 
http://www.mail-archive.com/[email protected]/ Reply to: [email protected] If 
Questions, contact Mike Russell, CHP at [email protected]
--- NOTICE ---

This message is for the designated recipient only and may contain confidential, 
privileged or proprietary information.  If you have received it in error, 
please notify the sender immediately and delete the original and any copy or 
printout.  Unintended recipients are prohibited from making any other use of 
this e-mail.  Although we have taken reasonable precautions to ensure no 
viruses are present in this e-mail, we accept no liability for any loss or 
damage arising from the use of this e-mail or attachments, or for any delay or 
errors or omissions in the contents which result from e-mail transmission.


-----------------------------------------
The information contained in this e-mail, including any
attachment(s), is intended solely for use by the named
addressee(s).  If you are not the intended recipient, or a person
designated as responsible for delivering such messages to the
intended recipient, you are not authorized to disclose, copy,
distribute or retain this message, in whole or in part, without
written authorization from PSEG.  This e-mail may contain
proprietary, confidential or privileged information. If you have
received this message in error, please notify the sender
immediately. This notice is included in all e-mail messages leaving
PSEG.  Thank you for your cooperation.

Reply via email to