What do you use to count smears for alpha/ beta activity? Ludlum 3030, Protean WPC-9550, Tennelec 5XLB, iSolo
Do you have a limit on the activity (dpm) that can be counted using a smear counter? 250,000 dpm And if you have a limit on activity, what is the limit and how do you count smears above the activity limit (beta) for alpha? Direct measurement with an ion-chamber, take a smaller sample & apply a scaling factor David Brehm Fort Calhoun Nuclear Station Office: 402.533.7582 Cellular: 402.214.0107 Pager: 402.561.3310 From: [email protected] [mailto:[email protected]] On Behalf Of Byrum, William F Sent: Monday, August 27, 2012 7:46 AM To: [email protected] Subject: Powernet: Alpha Counting Duke Energy request to following information: What do you use to count smears for alpha/ beta activity? Canberra iSolo, Ludlum 3030P, other? Do you have a limit on the activity (dpm) that can be counted using a smear counter? And if you have a limit on activity, what is the limit and how do you count smears above the activity limit (beta) for alpha? Bill Byrum, CHP,RSO EnRad Laboratories Duke Energy [email protected]<mailto:[email protected]> Phone 980.875.5811 ---------------------------------------------------------------------- This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, or acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.
<<inline: image002.gif>>