At Palo Verde, many years ago, we did use a type of check value that was placed 
in the opening of each drain. We had to remove them due to design configuration 
control and that they would affect the operation of the drain system. 

Jeffrey D. Norwood
Health Physicist-Senior
PVNGS RP Dosimetry 


Arizona Public Service Company
5801 S. Wintersburg Rd., M.S. 6107
Tonopah, AZ, 85354-7529

Tel: 623-393-2635
Fax: 623-393-2624
Pager: 1-877-443-8336
mailto:jeffrey.norw...@aps.com


-----Original Message-----
From: Aguilera, Roger [mailto:raaguil...@stpegs.com] 
Sent: Wednesday, September 21, 2016 8:38 AM
To: powernet@HPSpowernet.org
Subject: [powernet] Floor Drain Devices

____________________________________________________
USE CAUTION - EXTERNAL 
SENDER:(powernet-return-388-Jeffrey.Norwood=aps....@hpspowernet.org) 

Do not click on links or open attachments that are not expected.

For questions or concerns, please email the APS Cyber Defense Center team at 
a...@apsc.com <mailto:a...@apsc.com> or contact the APS Helpdesk.
____________________________________________________

Does anyone use devices in their floor drains that prevent positive air flow 
out of the drain but allows the drain to work as designed.

We at STP find particles around the floor drain due to positive air flow up 
through the drain

There are rubber check valves we are researching 

Thanks Roger

Sent from my iPhone
Powernet - a service of the Health Physics Society Power Reactor Section

To post message: Send or Reply to: powernet@hpspowernet.org To unsubscribe: 
send message to powernet-unsubscr...@hpspowernet.org
archive(Nov2015->): http://www.mail-archive.com/powernet@hpspowernet.org/
archive(<Oct2015): http://www.mail-archive.com/powernet@hps1.org/
If questions, contact E. Scott Medling, CHP at medl...@hps1.org


--- NOTICE ---

This message is for the designated recipient only and may contain confidential, 
privileged or proprietary information.  If you have received it in error, 
please notify the sender immediately and delete the original and any copy or 
printout.  Unintended recipients are prohibited from making any other use of 
this e-mail.  Although we have taken reasonable precautions to ensure no 
viruses are present in this e-mail, we accept no liability for any loss or 
damage arising from the use of this e-mail or attachments, or for any delay or 
errors or omissions in the contents which result from e-mail transmission.


Powernet - a service of the Health Physics Society Power Reactor Section

To post message: Send or Reply to: powernet@hpspowernet.org
To unsubscribe: send message to powernet-unsubscr...@hpspowernet.org
archive(Nov2015->): http://www.mail-archive.com/powernet@hpspowernet.org/
archive(<Oct2015): http://www.mail-archive.com/powernet@hps1.org/
If questions, contact E. Scott Medling, CHP at medl...@hps1.org

Reply via email to