Hello Josafat -
On Tue, 12 Oct 1999, Josafat Timotius wrote:
> Hi Hugh ,
>
> Thank you for your prompt replay. So, if i want to enforece strict session
> limit, which NAS-Type value should i use for my Remote Annex 6300 ?
I would try "NasType Bay" together with the relevant SNMP configuration in the
NAS. Note that Bay, Bay5399SNMP and Bay8000SNMP all call the same internal SNMP
query. Otherwise try either Bay4000SNMP or BayFinger.
> I had try my TotalControl with radiator, and everything work fine, when a
> user online, it show up in RADONLINE with right FRAMEDIPADDRESS
> informastion, and when i disconnect, the ACCOUNTING table got the stop
> session log correctly, including the right FRAMEDIPADDRES.
> Then i try my annex to accounting to radiator, the problem is :
> - when connected, my session show up in RADONLINE but with the blank
> FRAMEDIPADDRESS
> - when i disconenct my session, the accounting log show up, but with the
> FRAMEDIPADDRESS column blank.
I think the first thing to do is run Radiator with a debug trace level 4 and
look at the packet dumps to see exactly what is coming in from the NAS. Once we
know what attributes are in the packets, we can decide how best to deal with
the data. Note that if the NAS does not send Framed-IP-Address there is nothing
to be done.
hth
Hugh
--
Radiator: the most portable, flexible and configurable RADIUS server
anywhere. SQL, proxy, DBM, files, LDAP, NIS+, password, NT, Emerald,
Platypus, Freeside, TACACS+, PAM, external, etc etc on Unix, Win95/8,
NT, Rhapsody
===
Archive at http://www.thesite.com.au/~radiator/
To unsubscribe, email '[EMAIL PROTECTED]' with
'unsubscribe radiator' in the body of the message.