One thing that you might think about doing where the feedline leaves
the tower is to have a 270 degree loop where it leaves the tower and
bring the feedline off the tower at an angle of 90 degrees from the
tower leg. It will provide some choke effect to any currents that
might run down the cable and possibly reduce the currents that would
travel into the building.
Then where the feedline enters the building a polyphaser rated for the
radio power and frequency.
The suggestion of a surge protector on the AC mains is a good idea along
with on any phone lines that are connected to the unit for phone patch
or control.