I spent years with just a 50uA panel meter with lead wires and pins on the end -- sticking the pins in the right socket positions to take the readings. Not fun, but when I was broke in and just out of college it worked a lot better than spending money on a test set.

I never met a Mitrek receiver that didn't reasonably well as low as the helical resonators would tune. They'd lose a little sensitivity, but if the helicals didn't bottom out, they worked. That was my limiting factor. Transmitters seemed to always work, though the PA produced more heat as they got farther away from their comfort zone.

On Apr 29, 2008, at 7:47 PM, emt747 wrote:

Hello all,

4 questions:

1- Has anybody had any luck tuning the TX down to 438.XXX?

2- What kind of RX sens. is expected on 448.XXX? I am getting around .50uV

2- Does anybody have any tips on tuning the Mitrek without the test set?

3- Does anybody have a test set for sale?

I am working with T34JJA3900DK,T34JJA3900DL,T34JJA3900AK

Any help or ideas would be great.

Thanks,

Brent




--
Cort Buffington
H: +1-785-838-3034
M: +1-785-865-7206




Reply via email to