I have been able to move a 450-470 Mitrek down to as low as 420.  I use a 
spectrum analizer to sniff the signal until the meter reads.  Yes it is not as 
sensitive at 420.  0.6 to 0.7 but is great for links.  I used a Simpson 260 for 
years with the correct diameter probes.  You don't want them to slip and short 
anything.  A 450 unit will give about .35 or so at 445.  The multiplier stage 
is the key to getting good sens.  You really need do the final sens setting by 
peaking the two adjustments.  
Ralph, W7HSG
 -------------- Original message ----------------------
From: "emt747" <[EMAIL PROTECTED]>
> Hello all,
> 
> 4 questions:
> 
> 1- Has anybody had any luck tuning the TX down to 438.XXX?
> 
> 2- What kind of RX sens. is expected on 448.XXX? I am getting around .50uV
> 
> 2- Does anybody have any tips on tuning the Mitrek without the test set?
> 
> 3- Does anybody have a test set for sale?
> 
> 
> I am working with T34JJA3900DK,T34JJA3900DL,T34JJA3900AK
> 
> Any help or ideas would be great.
> 
> Thanks,
> 
> 
> Brent
> 
> 