Jan-Frode Myklebust wrote: [...] >> 3. _Not_ have an alarm situation in the SAN? > > No, not sure. Haven't tested that one. But I know I've tested rebooting > the switches between host and ds4800 one by one, without causing > problems on the hosts.
Yes. Pulling fiber cables and re-inserting them (which would give the same effect) works fine here, too. The only thing which doesn't work here is changing the preferred path (which is rather important to be able to level I/O pressure on controllers without generating false alarms). -- Regards, Troels Arvin <[EMAIL PROTECTED]> http://troels.arvin.dk/ _______________________________________________ rhelv5-list mailing list [email protected] https://www.redhat.com/mailman/listinfo/rhelv5-list