On Mar 5, 2013, at 11:09 39, Rob Landry wrote:

> The original switch appears to be an early model with a different style of 
> connectors on the back. It works reliably with Wireready, or with commands 
> manually entered via Putty, but not with Rivendell.

Serial buffer overflow in the original model, I'll bet.  Try running it at 2400 
bps.

Cheers!


|-------------------------------------------------------------------------|
| Frederick F. Gleason, Jr. |               Chief Developer               |
|                           |               Paravel Systems               |
|-------------------------------------------------------------------------|
|          A room without books is like a body without a soul.            |
|                                         -- Cicero                       |
|-------------------------------------------------------------------------|

_______________________________________________
Rivendell-dev mailing list
[email protected]
http://lists.rivendellaudio.org/mailman/listinfo/rivendell-dev

Reply via email to